How to Check and Test a Hydraulic Cylinder for Internal Leakage

When inspecting internal leakage in a hydraulic cylinder, one should first record any abnormalities and the test conditions, and then carry out appropriate isolation tests to confirm whether fluid is leaking past the piston or through other internal passages within the cylinder. Drift, pressure drop and localised overheating can all provide clues, but none of these phenomena alone is sufficient to confirm damage to the piston seal. A reliable diagnosis requires distinguishing the effects of the hydraulic cylinder, control valves and test equipment, and making a judgement based on the pressures in both chambers, position, temperature and the necessary leakage flow rate.

This GY Hydraulic guide focuses primarily on common single-rod, double-acting piston cylinders, i.e. hydraulic cylinders where the piston rod extends from only one end and both extension and retraction are driven by hydraulic fluid. Single-acting piston cylinders, multi-stage telescopic cylinders, and designs featuring special built-in valves require corresponding test procedures. The four test methods are different diagnostic tools; this does not mean that every hydraulic cylinder must undergo all tests in sequence.

Table of Contents

What Internal Leakage Is and Why It Matters

Hydraulic Cylinder Leakage

Internal leakage in a hydraulic cylinder occurs when hydraulic fluid flows through internal pathways it should not. A common form is piston seal bypass, whereby fluid flows from the side of the piston with higher pressure, bypassing the seal, and towards the side with lower pressure. The piston is the component within the cylinder barrel that bears the hydraulic pressure and drives the piston rod; the cylinder barrel is the tube that houses it and allows it to move. Unlike external oil leakage, internal leakage may leave the surface of the hydraulic cylinder dry.

Internal leakage may reduce the effective flow rate available for driving the load; flow rate refers to the volume of hydraulic fluid passing through per unit of time. For example, when there is a sustained pressure differential between the two sides of the piston, a portion of the supplied fluid bypasses the piston and cannot be fully utilised to drive the load; the system may also generate additional heat. This may also affect thrust, speed and the ability to maintain position. However, the piston seals are not the only potential pathways; internal static seals between the piston and the rod, internal oil passages or specialised valves should also be inspected in accordance with the schematic diagram. A static seal is a seal used at joints where there is no relative movement.

First, confirm the design of the model and the permissible leakage requirements before determining whether a fault has occurred. Permissible leakage performance varies between different seal designs; the permissible leakage rate for a particular type of metal piston ring cannot be directly applied to another hydraulic cylinder with soft seals.

Symptoms That Suggest Piston-Seal Bypass

Symptoms worth investigating include: the piston rod continuing to move in the absence of a control signal, slowed movement under load, reduced holding capacity, or abnormal overheating under certain operating conditions. Slow movement without a control signal is commonly referred to as ‘drift’. However, these phenomena may also be caused by control valves, insufficient oil supply, external leakage or load-related issues. The most valuable first step is to record whether the anomaly occurs during the extension, retraction or holding phase, as well as the oil temperature and load at the time, rather than immediately ordering a seal kit.

hydraulic cylinder

For example, if the equipment only exhibits weak performance after the machine has warmed up, you should compare the oil supply pressure and flow rate under the same load; you cannot simply assume that the piston seal has failed just because ‘the problem only occurs when it’s hot’. Slow or weak operation may be due to insufficient flow, insufficient pressure, internal leakage or circuit restrictions, and you need to narrow down the possible causes by analysing pressure, flow and temperature together.

Even in the absence of drift, piston bypass cannot be ruled out. In certain single-rod cylinders under compressive load, where both chambers are full of oil and the ports are sealed, the cylinder may temporarily cease movement following the redistribution of internal oil. Internal oil flow and sustained displacement are not one and the same. When making a judgement, one must consider not only the movement but also the pressure in both chambers and whether the circuit permits oil to flow out.

Safety Steps Before Testing a Hydraulic Cylinder

Before testing, first check the equipment manual, hydraulic schematics, hydraulic cylinder model and test objectives. The hydraulic schematics show how the oil circuits are connected and can help you identify valves that may trap pressure. Isolate the power supply and prevent accidental start-up; position the working equipment in the specified location and use appropriate mechanical supports. Accumulators are components that store hydraulic energy; where such a configuration is present, the stored energy must be discharged in accordance with the manufacturer’s procedures.

Before installing or replacing test lines, ensure that the relevant oil chambers and branches have been depressurised. A main pressure gauge reading zero does not necessarily mean that oil chambers isolated by check valves or load-holding valves are also pressure-free; load-holding valves are components that help maintain the load’s position and control its descent. Do not check pressure by loosening fittings, nor should you use your hands to locate pressurised leaks. High-pressure hydraulic fluid can penetrate the skin; if hydraulic fluid injection is suspected, seek immediate medical attention and specify that hydraulic fluid is involved.

Controlled drift testing also requires specially designed anti-fall measures and a safety zone. If mechanical supports bear the entire load, the measured value will no longer reflect the hydraulic load-holding capacity under actual operating conditions; conversely, removing necessary supports for the purpose of measurement may create a risk of the load falling. The test positions and protective measures specified by the original equipment manufacturer must be used; where it is not possible to meet both measurement and safety requirements simultaneously, an appropriate test rig should be used instead. Novices may prepare documentation and record readings, whilst reconfiguring hydraulic circuits and conducting pressure tests must be carried out by trained personnel.

Hydraulic Cylinder Leakage

Test 1: Check Cylinder Drift Under a Controlled Load

This test is designed to observe whether the piston rod moves of its own accord after you have stopped issuing movement commands, and by how much. It can help you identify position-holding anomalies, but you should not conclude that the piston seal is leaking oil based solely on slippage. You can prepare and record the results by following the four steps below; the load test should be carried out by trained personnel.

  1. First, establish the test conditions; do not add weights arbitrarily. Consult the machine manual to confirm the test load, the working arm’s orientation, the piston rod’s extended position, and whether the pump needs to be stopped or the power switched off during the test. Fall prevention measures must also be set up in accordance with the machine’s test protocol; do not remove supports on your own to observe any slippage. If the supports are already fully bearing the load, the fact that the piston rod does not move cannot be taken as evidence that the position is being held correctly under load. Prior to testing, ensure that the oil temperature has stabilised in accordance with the manual’s requirements to avoid misinterpreting positional changes caused by oil cooling and contraction as leaks.

  1. Measure the position of the piston rod; do not simply observe how far the working arm has descended. What you need to measure is the displacement of the piston rod relative to the cylinder body. Prior to testing, maintenance personnel must install the measuring equipment whilst the machine is in a safe, isolated state. For minute movements, use a dial gauge—an instrument capable of displaying minute displacements—or a suitable displacement sensor. Record the initial position, then read subsequent changes from a safe position. Do not stand beneath the lifting components to measure with a ruler, nor should you directly use the lowering distance of the working arm’s end to substitute for the rod displacement, as link ratios and pin clearances will affect the results.

  1. Record the time and displacement to calculate the speed of movement. For the observation period specified in the manual, record how far the piston rod has moved and whether it is extending or retracting. Average drift speed = displacement ÷ observation time. For example, assuming the piston rod moves 3 millimetres over 10 minutes, the average speed is 0.3 millimetres per minute. This is merely a demonstration of the calculation method; it does not represent actual test results, nor does it constitute a recommended test duration or pass criterion. Whether the cylinder passes the test must still be determined by reference to the requirements for the specific model.

Column Load in Hydraulic Cylinders
  1. Continue troubleshooting based on the results; do not rush to replace the seals. If the drift exceeds the limits specified in the manual, you will need to distinguish between internal leakage within the hydraulic cylinder, valve leakage and other causes. If there is no noticeable movement, this merely indicates that no significant drift was detected under these specific conditions; it does not prove that there is no internal leakage throughout the entire stroke. If the cylinder suddenly accelerates downwards during the test, new oil leakage occurs or the anti-drop device malfunctions, the test must be stopped immediately in accordance with the procedure. The manufacturer’s documentation also clearly distinguishes between seal issues, valve leakage and drift caused by temperature changes.

Test 2: Isolate the Cylinder from the Control Valve

If a hydraulic cylinder is slipping on its own and you are unsure whether to repair the cylinder or the valve, an isolation test can help narrow down the cause. The maintenance technician should, in accordance with the equipment specifications, isolate the hydraulic cylinder from the relevant control circuit for testing, and then compare any changes in displacement, pressure or leakage rate.

① Define What Is Included in the Test

First, take photographs of the connections between the hydraulic cylinder, oil lines and nearby valves. Then, ask the maintenance technician to refer to the schematic diagram to confirm where to isolate the system, where to measure pressure, and how to protect the load and release residual pressure. Both working oil circuits must be checked; if there are pilot circuits that open control valves, these must also be included in the analysis. Simply shutting off one oil circuit does not necessarily constitute a complete isolation.

For example, when a load-holding valve is fitted directly to the hydraulic cylinder, the test subject may still include this valve even if the external oil lines are disconnected. If an anomaly is detected in this situation, it is necessary to further distinguish whether the leak originates within the cylinder or the valve; one cannot immediately conclude that the piston seal is damaged.

② Choose Instruments for the Measurement

You should first clarify what you intend to measure before selecting the appropriate tools. If you are merely recording stroke travel, you will need a suitable displacement measurement device; if you wish to determine how the pressure in the two chambers varies, you will need corresponding pressure measurement points; and if you wish to ascertain the volume of oil lost, you will require instruments suitable for measuring low flow rates.

  • Pressure gauges: The range must cover the anticipated maximum pressure and allow for clear observation of the required changes. When assessing the pressure in both chambers, it is not sufficient to rely on a single gauge at the pump outlet.
  • Test valves, fittings and plugs: These must be compatible with the type of oil port and the test pressure. Dust plugs used during transport cannot be substituted for pressure-rated plugs. Any oil leakage from the test valve itself will also affect the results.
  • Flow measurement devices: Check the minimum flow rate it can accurately measure, as well as its pressure rating, oil compatibility and outlet resistance. Back pressure caused by outlet resistance will alter the test conditions.

For example, if you use a gauge designed to measure high flow rates in the main circuit to check for minor seal leaks, you may see a reading of zero. This may simply mean the gauge is unable to detect the leak and should not be taken as definitive proof that there is no leak.

③ Compare Results Without Overstating Them

Steering Hydraulic Cylinders

Before reconfiguring the oil circuit, you must first shut down the system in accordance with procedures, isolate the power supply, support the load, and confirm that the relevant oil chambers have been depressurised. A qualified technician should then establish the prescribed test connections and pressure protection. Do not block the return line yourself whilst continuing to supply oil, nor should you adjust the load-holding valve to ‘test whether slippage occurs’. When comparing results before and after, endeavour to maintain the same oil temperature, load, piston position and observation time, and record the actual differences:

  • No slippage after isolation: The original circuit may have contributed to the problem, but blocking the oil line may also have temporarily restricted movement; therefore, this does not guarantee that the piston seal is intact.
  • Slippage persists after isolation: Continue inspecting the hydraulic cylinder whilst ruling out the effects of test valve leakage, external leakage and temperature fluctuations.

This step helps you decide where to investigate next; you cannot simply decide which part to replace based on whether the cylinder ‘moves or does not move’. Parker’s diagnostic documentation also notes that drift, which may appear to be a piston leak, could originate from other components in the circuit.

④ Know the Limits of End-of-Stroke Tests

If the hydraulic cylinder consistently develops problems when extended halfway, you should record this position and inform the test personnel. Inspecting only at the fully extended or fully retracted positions may overlook scratches or localised deformation in the middle section of the cylinder barrel. Passing an end-of-stroke test merely indicates that the cylinder meets the relevant requirements at that specific position and under those specific conditions.

When inspecting the middle section, specialised fixtures capable of withstanding hydraulic thrust, or a purpose-designed test circuit, should be used. Do not force the cylinder to stop by using wooden blocks, ordinary bench vices or by clamping the piston rod. The specific test positions and methods should be determined by maintenance personnel based on the fault symptoms and the manufacturer’s requirements.

Test 3: Perform a Pressure-Decay Test

A pressure decay test involves establishing a specified pressure and, after isolating the pressure source in accordance with the procedure, recording the change in pressure over time. It is suitable for comparing pressure retention performance under controlled test conditions. If the pressure source continues to supply oil, a stable pressure reading on the pressure gauge does not prove the absence of leaks, as the oil supply may be compensating for the volume of oil lost through leakage.

Prior to testing, the system should be vented, and it should be confirmed that the temperature, piston position and mechanical constraints comply with the procedure. Record the pressures in both chambers, the oil temperature and the position, rather than merely taking a single gauge reading. For example, if the pressure on the high-pressure side falls whilst that on the other side rises—after ruling out the effects of displacement, temperature and the test branch—this may support further investigation into cross-leakage between the two chambers; if a pressure drop is observed at only one measurement point, it is not yet possible to distinguish between an external leak, a leak in the isolation valve or an internal leak.

Pressure variations are also influenced by fluid compression, hose elasticity and the volume under pressure. Hoses expand slightly under pressure, and fluid is not entirely incompressible; therefore, initial variations and the steady-state phase should be distinguished in accordance with the procedure. In the absence of known volumes, corresponding models and verification, do not directly convert ‘pressure drop per minute’ into ‘oil leakage rate per minute’, nor should you arbitrarily set generic pressure drop pass/fail thresholds.

Test 4: Use Temperature, Sound, or Flow to Detect Bypass

Temperature and sound are useful for locating anomalies, whilst flow rate can provide more direct quantitative information under appropriate test conditions. When using a thermal imager, one should compare temperature distributions under identical operating conditions and similar surface conditions, and then make a judgement in conjunction with the oil circuit diagram. For example, a sustained rise in temperature in a branch line where no flow is expected may indicate the need for inspection; however, the heat may also originate from valve throttling, friction, external heat sources or conduction. Thermal imaging displays surface temperature distributions and cannot ‘see’ oil leaks through the cylinder barrel directly.

When using a contact-type ultrasonic tester, specialists can compare structural sound transmission at different locations and under different conditions to identify clues of abnormal flow. Ultrasonic sound refers to sound beyond the normal range of human hearing; however, readings may still be affected by normal flow through valve orifices, as well as pump and mechanical vibrations. Comparisons must be made using the same measurement points, contact methods and instrument settings; one must not rely solely on a ‘louder hissing sound’ to conclude that a piston seal is damaged.

If measuring bypass flow, this should be carried out under conditions where the hydraulic cylinder has been limited to its travel as per procedure, the pressure differential is controlled, and the measurement path is clearly defined. When the piston is moving normally, the outlet flow includes working fluid displaced by the piston and cannot be entirely attributed to leakage; similarly, flow detected in the main return line cannot automatically be attributed to a specific hydraulic cylinder. The measurement location, pressure differential, oil temperature and back pressure must be recorded for the results to be comparable.

GUOYUE Double Acting Hydraulic Cylinders
GUOYUE Double Acting Hydraulic Cylinders

How to Separate Cylinder Leakage from Valve Leakage

The key to distinguishing between cylinders and valves lies in verifying their leakage behaviour under specified conditions. Directional control valves regulate the flow of hydraulic fluid, whilst load-holding valves assist in load control; the internal leakage pathways of these two components differ from the cross-leakage between the two chambers of a piston. It is necessary to consider the neutral position function—that is, the interconnection status of the various ports when the directional control valve receives no actuation command—to determine whether the equipment is intended to seal the cylinder ports. Leakage permitted by the design must not be mistaken for a valve fault.

For example, if the same hydraulic cylinder meets the relevant leakage requirements under a qualified independent test configuration but exhibits abnormalities when reconnected to the original circuit, the focus of the investigation should shift to the valve block, pilot control and connecting oil lines. However, if the independent test only covers the end of the stroke, whilst the original fault occurred in the middle section, the two conditions are not equivalent, and the possibility of a cylinder fault cannot be completely ruled out. Conversely, confirming internal leakage in the cylinder does not necessarily mean that the valve block is functioning correctly; both faults can co-exist.

It is recommended that the report clearly specify ‘confirmed leakage paths’ and ‘conditions not yet covered’. For example, one might state: ‘Under specified oil temperature and position, the cylinder’s dedicated test met the corresponding requirements; abnormal position holding in the original circuit remains to be investigated’, rather than making a general statement such as ‘the hydraulic cylinder is absolutely normal’. Such wording helps maintenance personnel focus their next round of testing on the evidence that is genuinely missing.

Hydraulic Cylinder Leakage

Interpreting Results Without Creating a Pressure Hazard

The aim of the diagnosis is to identify the leak path, not to raise the pressure to a level sufficient to reveal the fault. First, check that the test conditions are valid, then assess what conclusions can be drawn from the results. If circuit connections, pressure protection or load safety have not been verified, continuing to collect readings will not make the diagnosis any more reliable.

a. Understanding Why Trapped Pressure Can Increase

In a standard single-rod cylinder, the effective pressure-receiving areas on either side differ: the rodless chamber utilises nearly the entire piston area, whilst the rod chamber must account for the area occupied by the piston rod. The effective pressure-receiving area is the area over which the hydraulic pressure actually generates thrust. If fluid is supplied to the side with the larger area whilst the fluid on the side with the smaller area is trapped, the trapped side may experience a pressure higher than the supply pressure. This is known as pressure build-up or the pressure amplification effect; the local pressure does not necessarily equal the pump outlet reading.

Parker specifically notes that, in double-acting telescopic cylinders, restricted return flow may result in dangerous pressure build-up; for standard single-rod cylinders, the pressure build-up must also be analysed in conjunction with the area difference and force distribution. The relief valve in the original system may not necessarily protect the isolated oil chamber, as it can only function effectively when it is effectively connected to that chamber. A relief valve is a device that diverts oil and limits pressure once set conditions are met. Therefore, whilst a plug may be certified as pressure-resistant, this does not mean that ‘continuing to supply oil after sealing’ constitutes a safe test.

b. Match Each Observation to Its Limits

The table below is intended to organise the evidence; it does not provide general pass/fail limits. Before drawing any conclusions, the test circuit, oil temperature and measurement conditions must be verified.

Observation Conclusions that can be supported What cannot yet be directly proven What should be verified next
Drift observed in the original circuit The ability to maintain position under specified operating conditions requires assessment Does not, on its own, prove damage to the piston seal Model-specific limits, external leakage, temperature variations and valve circuits
No further drift after isolation Altered hydraulic circuit boundaries have affected movement Does not prove that there is no cross-leakage between the piston’s two sides Pressure in both chambers, enclosed volume and independent leakage tests
Pressure decreases over time Changes in pressure conditions within the test range Cannot pinpoint the cylinder or valve based on a single gauge reading Temperature, position, isolation components and external connections
Pressure differential between chambers narrows Pressure redistribution may be occurring Cannot directly quantify bypass flow whilst the piston is moving or during temperature changes Check for displacement, test valve leakage and inter-chamber flow
Localised thermal or acoustic anomalies Areas of concern warranting further investigation Cannot prove that a specific seal has failed Normal throttling, mechanical vibration, heat conduction and verification measurements
Excessive cross-chamber flow measured during a qualified specialised test Leakage paths within the cylinder require repair Flow alone cannot distinguish between seal damage and cylinder barrel damage Structural diagrams and disassembly inspection results

For example, when the pressures in the two chambers are nearly equal, a single-rod cylinder may still generate net thrust due to differences in area. Do not interpret ‘equal pressure’ as ‘zero force’, nor should you assume that the seal test has been passed on this basis. Instead, you should first confirm what pressure differential the test was intended to maintain, and then discuss whether the actual readings meet expectations.

c. Stop Before the Test Becomes Uncontrolled

The test procedure should specify in advance the conditions for stopping the test, such as pressure, position and temperature. In the event of unexpected movement, an abnormal rise in readings, gauges approaching the limits of their permissible range, new external leaks or abnormalities in the mounting fixture, pressurisation should be halted in accordance with the established procedure, and pressure should be relieved in a controlled manner from a safe position. Do not approach pressurised connections to inspect them, nor should you temporarily tighten leaking joints. The pressure test area requires appropriate isolation and protection, and the condition of test fittings and hoses should also be checked.

Upon completion, confirm that both chambers and associated branches have been depressurised before dismantling the test apparatus. Record the hydraulic cylinder model, connection diagram, load and direction, piston position, pressure in both chambers, oil temperature, observation time and instrument data. Such records support subsequent verification; a simple statement that ‘pressure could not be maintained’ is insufficient to determine which component requires replacement.

What to Inspect After Internal Leakage Is Confirmed

China Loader Hydraulic Cylinder Manufacturer

Once internal leakage has been confirmed, first record the test results and the location of the fault, then disassemble and inspect the unit in accordance with the maintenance manual. The inspection can be divided into the following three steps:

  1. Inspect the piston seals, seal grooves and connecting structures. Pay particular attention to whether the seals show any cuts, wear, extrusion, hardening or abnormal swelling. Extrusion refers to damage caused when a seal is forced into the clearance by pressure. At the same time, inspect the seal grooves, as well as the internal seals and locking mechanisms at the connection between the piston and the rod. Take photographs before removing the seals to record their installation orientation and the distribution of damage, thereby avoiding the loss of evidence for assessment after cleaning.
  2. Inspect the cylinder bore, piston and guide components. Guide rings or bushings are responsible for maintaining the alignment of moving parts and must not be relied upon by seals to bear lateral forces. If leakage is evident in the middle section but performance is satisfactory at the end points, focus on checking the corresponding sections for scoring, dimensional accuracy and deformation; if wear is concentrated on one side, investigate possible installation misalignment and guide clearance. Even after discovering damage to the piston seals, it is still necessary to verify that the cylinder bore meets specifications.
  3. Identify the cause of the damage before selecting replacement parts. Correlate the damage with hydraulic fluid contamination, temperature, pressure and material compatibility. For example, sand particles and metal debris may damage the cylinder walls and seals, whilst sharp edges or incorrect assembly may also cause cuts to new components. When selecting new seals, verify the hydraulic cylinder model, seal groove dimensions, seal material and the hydraulic fluid actually in use, and address the root cause of the damage.

When consulting GY Hydraulic regarding product configuration or replacement requirements, please have the nameplate, original drawings, test connection diagrams, leakage records and photographs of the damage to hand to assist in determining the required parts and subsequent verification criteria.

FAQs: How to Check a Hydraulic Cylinder for Internal Leakage

Can a cylinder have internal leakage without drifting?

Yes. In certain single-rod cylinders with two oil-filled chambers, sealed ports and subjected to a compressive load, a bypass may cause pressure redistribution, followed by no sustained visible movement; external control systems may also compensate for the leakage. Whether drifting occurs depends on the design, load direction and fluid flow path; therefore, the absence of piston rod movement cannot be taken as universal evidence of a valid seal across all designs.

There is no standard drift speed applicable to all hydraulic cylinders. The threshold depends on the machine’s function, cylinder bore, load, temperature and the specified measurement location. Refer to the requirements in the relevant model’s manual; where no guidance is available, simply record the measurement results and request an engineering assessment—do not arbitrarily set a ‘normal’ limit such as ‘no more than X millimetres per minute’. Furthermore, should positional changes occur that endanger personnel or equipment, the cylinder must not continue to be used merely because the drift rate is below a value found online.

Yes. Oil temperature alters viscosity—that is, the thickness of the oil as it flows; temperature changes also alter the volume of the enclosed oil and affect the sealing condition. Therefore, data from a warm and a cold machine cannot be directly compared. During testing, the temperature should be stabilised in accordance with the model specifications, and temperature changes should be recorded to avoid mistaking pressure drops or positional changes caused by cooling as actual leakage.

It can help narrow down the scope of the investigation, but cannot guarantee precise localisation of the piston seal. Surface reflections, coatings, external heat sources and heat conduction may all affect the image. For example, heat at the cylinder end may result from heat transfer from a nearby valve block. Temperature changes should be observed under comparable operating conditions and then verified using pressure or flow tests with a clearly defined path; the absence of hotspots does not rule out a low-flow bypass.

A single pressure gauge is usually insufficient. It reflects the pressure at the measurement point but cannot directly indicate which internal passage the fluid is escaping through. If the measurement point is not on the side of the isolated cylinder, it may not even be measuring the target oil chamber. A judgement should be made based on the connection diagram, the pressures in both chambers, their positions and temperatures; if necessary, the leakage flow rate should be measured.

It can cause similar symptoms. Air is more compressible than hydraulic oil and may cause the movement to appear spongy, resulting in initial displacement, delayed response or pressure fluctuations. The system should be bled in accordance with the procedure for that specific model before retesting; bleeding must not be carried out by loosening fittings whilst the system is under pressure. If air continues to enter, the source of the air ingress must also be investigated.

Sealing a port may only be an appropriate measure within a verified test protocol. Verification is required regarding load support, local maximum pressure, pressure protection, measurement and controlled pressure relief paths, and the use of suitable pressure-resistant components. Transport plugs intended for dust protection must not be used as test plugs. Do not supply oil to one port whilst another is sealed in an attempt to assess the seal by checking whether the cylinder ‘moves’.

Common factors include fluid contamination, cylinder barrel damage, excessive clearance, installation-related nicks, lateral loads, abnormal temperatures or pressures, and material incompatibility with the fluid. The appearance of damage can only provide a general indication; it should be confirmed in conjunction with actual measurements and operating conditions. For example, if a new seal quickly develops scuff marks in the same direction, the guides, cylinder barrel and installation alignment should be checked; one should not simply replace it with a seal from another brand and continue testing.